在Hauhinco传统与创新是互不分离的。Hauhinco是1908年在德国斯普罗克霍威尔,鲁尔矿业的摇篮成立的。至今,Hauhinco仍旧牢记自己的由来。再过去的100余年间,公司经历了很多组织结构和市场环境的变化,并仍旧不断地推陈出新,为市场带来创新性的产品。这些经验使得Hauhinco在市场中独树一帜。
Hauhinco是一家拥有悠久历史的成功的中型公司。如今,Hauhinco是世界领先的水液压应用领域供应商。我们的高压柱塞泵,阀以及系统被广泛地应用于世界各地的井下煤矿以及工业领域。而我们的员工正是我们成功的关键。
The pump unloader valve, and the pilot valve form a valve unit controlling a pump in a pressure supply system with a pressure accumulator. Depending on the system pressure, the valve controls the working cycle of the pump, „pressure build up“, „load accumulator“ or „depressurised bypass“. The P-connector is connected to the pressure port of the pump, the A-connector to the pressure line of the system and the T-connector to the pressure-free tank.
The flow of the pump enters the pump unloader valve at the P-connector. The pump flow is connected to the pressure port of the pilot valve (1) via the filter (5). In the circulation position, the control piston (3) of the 2/2-way valve (2) is pressure-relieved on the control side, the 2/2- way valve is open and the pump fl ow is pressureless discharged from P to T. By switching over the pilot valve (1), the piston (3) is pressurized on the control side and the 2/2-way valve (2) closes and blocks the connection P to T. At the same time, the check valve (4) opens and connects the lines P to A. The pump fl ow is supplied via the A connection to the system.
General | |
Weight | see Order information |
Installation position | any |
Ambient temperature | -10 to 50°C (hydraulic fl uids, heed standard requirements) |
Material Valve parts Material Seals | Stainless steel NBR, PTFE, PUR |
Hydraulic | |
<h4Pump unloader control DN40, PN420 | |
Hydraulic pressure connector P, A, MA | ≤ 420 bar |
Hydraulic pressure connector Y | ≤ 2 bar |
Hydraulic pressure connector | ≤ 2 bar |
Direction of flow | P→T, P→A |
Pressure fluid - Medium - Temperature range - Medium - Quality - min. filter fineness connection P, A - min. filter fineness Pilot control valve | Water, HFA 5 to 40°C see Hauhinco media requirement, water, HFA Filter fineness 100µm Filter fineness 25µm |
Pressure fluid - Medium - Temperature range - Medium - Quality - Viscosity | Mineral oil HLP according to DIN51624-2 5 to 50°C Cleanliness class -/19/16 according to ISO 4406 0.6 up to 100 mm2/s |
max. switching rate of the valve unit | 0,2 Hz |
Use of other pressure fluids on request. | |
Note: The maximum decrease volume flow of the consumer and the size of the pressure accumulator control the switching rate of the pump circulation control system. |
Description | Nominal size | Weight | Max. pressure | Basic position | Voltage | Note | Article number |
---|---|---|---|---|---|---|---|
Pump unloader control | DN40 | 65 - 134.7 | 420 |