在Hauhinco传统与创新是互不分离的。Hauhinco是1908年在德国斯普罗克霍威尔,鲁尔矿业的摇篮成立的。至今,Hauhinco仍旧牢记自己的由来。再过去的100余年间,公司经历了很多组织结构和市场环境的变化,并仍旧不断地推陈出新,为市场带来创新性的产品。这些经验使得Hauhinco在市场中独树一帜。
Hauhinco是一家拥有悠久历史的成功的中型公司。如今,Hauhinco是世界领先的水液压应用领域供应商。我们的高压柱塞泵,阀以及系统被广泛地应用于世界各地的井下煤矿以及工业领域。而我们的员工正是我们成功的关键。
The valve piston (2) guided within the valve body and cover (1) is adjusted by turning the handwheel (4) axially via the thread (3). By turning it clockwise, the valve is closed pressing the valve piston (2) into the valve seat (5). The thread (3) of the valve piston has a self-locking action; the hydraulic axial forces at the valve piston result in frictional forces within the thread (3) and on the piston seal (6) fixing the valve piston within the position. In addition, the valve piston can be fi xed via the locking screw (7). The proximity switch (8) is arranged in the bottom position and monitors the closed valve position. In order to keep the actuation forces at the valve to a minimum, for this valve the preferred direction of flow is to be selected from the B-channel to the A-channel; depending on the valve size this specification may vary, see Valve data. To enable adjustment under pressure for larger nominal value and thus larger hydraulic surfaces, these valves are additionally equipped with a bearing.
General | |
Weight | see Order information |
Installation position | any |
Ambient temperature | -10 to 50°C (hydraulic fl uids, heed standard requirements) |
Material Valve parts Material Seals | Stainless steel NBR, PTFE, PUR |
Hydraulic | |
Hydraulic pressure connector A, B | ≤ 320 bar, ≤ 500 bar, see Order information |
Direction of fl ow | A->B, see Order information |
Pressure fluid - Medium - Temperature range - Medium - Quality - min. filter fineness connection | Water, HFA 5 to 40°C see Hauhinco media requirement, water, HFA Filter fi neness 100µm |
Pressure fluid - Medium - Temperature range - Medium - Quality - Viscosity | Mineral oil HLP according to DIN51624-2 5 to 50°C Cleanliness class -/19/16 according to ISO 4406 0,6 bis 100 mm²/s |
Use of other pressure fl uids on request. | |
Ranges of application | |
Shut-o function | Monitoring of the closed valve position for a normal operation, e.g. pressure relief, ventilation, drain valve, pressure shut-off for safely shutting off a hydraulic system. Monitoring of the open valve position for the normal operation, e.g. safe pressure application, shut-off only during maintenance work. |
Throttle function | Setting of the volume flow as required, e.g. setting the speed of motion at the consumer. |
Included in the scope of supply | |
Mounting screws for the non-return valve |
Description | Nominal size | Weight | Max. pressure | Basic position | Voltage | Note | Article number |
---|---|---|---|---|---|---|---|
Throttle shut-off valve C-DR DN10 | DN10 | 2,0kg | 320 | 6274269 | |||
Throttle shut-off valve C-DR DN10 | DN10 | 1,8kg | 500 | 6398480 | |||
Throttle shut-off valve C-DR DN16 | DN16 | 5,7kg | 320 | 6606267 | |||
Throttle shut-off valve C-DR DN16 | DN16 | 7,3kg | 500 | 6603266 | |||
Throttle shut-off valve C-DR DN25 | DN25 | 320 | |||||
Throttle shut-off valve C-DR DN32 | DN32 | 14,5kg | 320 | 6603268 |