Pressure relief valves proportional actuated DN20-DN25 PN400

Features

  • Proportional controlled pressure relief valve
  • Seat valve with a leak-free, metallic conical seat seal
  • All parts are made of corrosion-resistant materials, and they are easily replaceable
  • Hydraulic accumulator as a preload element, adjustable accumulator pressure by proportional pilot valves
  • Attachment, structural plate form with Hauhinco connection diagram

Function

Pressure relief valve for the primary pressure setting at the hydraulic pumps and the pressure protection of the hydraulic drives, hydraulic components.

In the basic valve position, the hydraulic power of the hydraulic accumulator (7) acts on the piston valve (4) and transfers it to the valve piston (3). The valve seat (2) and the valve piston (3) form the valve seal at the conical surface. On the gas side, the hydraulic accumulator (7) has been prefilled with nitrogen and is preloaded hydraulically with the pressure setting on the liquid-side until the requested preset pressure „Pe“ is reached. The gas within the accumulator is compressible and acts as a flexible spring.

Within the operation of the valve, the system pressure „Ps“ enters the valve body (1) at the P-connector generating a hydraulic (opening) force at the valve seat area of the valve piston (3). The piston valve (4) maintains the valve piston (3) in the shut off basic position as long as the hydraulic opening force is < than the closing force at the piston valve (4). If the system pressure „Ps“ increases to the extent that the force ratio reverses to be opening force > closing force, then the valve piston (3) is pressed out of the basic position, lines P and T are connected thus opening the valve. The valve opening increases proportionally with increasing system pressure until the maximum admissible volume flow for the valve has been reached, see valve characteristic.

The pressure of the valve is set via the proportional pilot valves (5, 6). Thus, the pressure of the accumulator (7) is set. Depending on the pressure setting of the accumulator a hydraulic power is generated, which is transferred to the valve piston (3). From the control ratio „SK“ (see technical data) and the preset pressure „Pe“ follows the required accumulator pressure „Pap“.

 

Technical data

measured with HFA medium 97/3%, at 20°C

General

WeightDN20 22,8kg
DN25 35,8kg
Installation positionany
Ambient temperature-10 bis 50°C (hydraulic fl uids, heed standard requirements)
Material Valve parts
Material Seals
Stainless steel, bronze
NBR, PTFE, PUR

Hydraulic

hydraulic pressure connector P≤ 400 bar
hydraulic pressure connector T≤ 50bar (observe counterpressure within the pressure setting)
Setting range of hydraulic response pressure Pe30 – 400 bar
Control ratio SkDN20: 1:1,9 – 2,25 (area piston valve/valve piston)
DN25: 1:2,0 – 2,20 (area piston valve/valve piston)
Pressure range accumulator PSp14 – 200 bar
max. volume flowDN20 450 l/min
DN25 700 l/min
direction of flowP->T
Pressure fluid
- Medium - Temperature range
- Medium - Quality
- min filter fineness
Water, HFA
5 bis 40°C
see Hauhinco media requirement, water, HFA
Filter fineness 100µm
Pressure fluid
- Medium - Temperature range
- Medium - Quality
Mineral oil HLP according to DIN51624-2
5 to 50°C
Cleanliness class -/19/16 according to ISO 4406
Optional featuresPressure display „PSp“, see order data
Use of other pressure fl uids on request.

Included in the scope of supply

Mounting screws for the valves
Pressure setting according to customer specification
Factory test certificate on request

Versions

DescriptionNominal sizeWeightMax. pressureBasic positionVoltageNoteArticle number
Pressure relief valve DN20DN2022,8kg400--Setting range 30-400bar6602555
Pressure relief valve DN25DN2535,8kg400--Setting range 30-400bar6601235