Pressure reducing valves PN500

Features

  • Direct controlled pressure reducing valve.
  • All parts are made of corrosion-resistant materials, and they are easily replaceable.
  • Hydraulic accumulator as a preload element
  • Attachment, structural plate form or pipe connection

Control function

The Pressure reducing valve reduces the primary pressure on port P to a previously set secondary pressure in port A. For primary pressures up to 400 (500) bar, reduced pressures can be set between 20 and 350 (480) bar. A hydraulic accumulator (6), which is prefi lled with nitrogen on the gas side, serves as a preload element. The pressure in the hydraulic accumulator (6) is set by opening the adjusting screw (4). Readjustment of the set pressure is possible by releasing the pressure via the adjusting screw (5) into the tank connection (T).

In the basic valve position, pressure medium fl ows through the valve seat (2) from primary side (P) to secondary side (A). The pressure in the hydraulic accumulator (6) acts to surface (F1) of piston (3). The primary pressure acts to surface F2 and F3. As long as the primary pressure is lower than the set pressure, the valve bolt (1) remains open since the surface F1 to F2-F3 are balanced. When the set pressure in the hydraulic accumulator is reached or exceeded, the piston (3) and thus the valve bolt (1) moves and closes the open valve seat. In closed position, the primary pressure acts to surface (4). The surface F3 is just as large as the surface F4 so that the secondary pressure is kept constant by permanently opening and closing the valve bolt (1).

The pressure relief valve (7) prevents an unwanted pressure increase in the event of leaks at the valve seat. The excess pressure is discharged via the tank connection (T).

Technical data

measured with HFA medium 97/3%, at 20°C

General

Weight15,6kg
Installation positionany
Ambient temperature-10 bis 50°C (hydraulic fluids, heed standard requirements)
Material Valve parts
Material Seals
Stainless steel, bronze
NBR, PTFE, PUR

Hydraulic

Hydraulic pressure connector P≤ 500 bar
Hydraulic pressure connector A≤ 480bar
Hydraulic pressure connector T≤ 10bar
setting range of hydraulic response pressure Pa20 – 480 bar
control ratio:
- pressure reducing function (P-A)
- pressure relief function (A-T)

1:1
1:0,95
direction of flowP->A
max. volume flow200 l/min
Pressure fluid
- Medium - Temperature range
- Medium - Quality
- min filter fineness
Water, HFA
5 to 40°C
see Hauhinco media requirement, water, HFA
Filter fineness 100µm
Pressure fluid
- Medium - Temperature range
- Medium - Quality
- Viscosity
Mineral oil HLP according to DIN51624-2
5 to 50°C
Cleanliness class -/19/16 according to ISO 4406
0,6 bis 100 mm²/s
Use of other pressure fl uids on request.

Included in the scope of supply

Mounting screws for the valves
Pressure setting according to customer specification
Factory test certificate on request

Versions

DescriptionNominal sizeWeightMax. pressureBasic positionVoltageNoteArticle number
Pressure relief valve D500/30DN1615,6kg500--Setting range 30-480bar
Type: Plate-type
6262090
Pressure relief valve D500/30DN1615,6kg500--Setting range 30-480bar
Type: Pipe connection
6206530

Enquiry about: Pressure reducing valves PN500

If you need further information or have a specific request, we look forward to hearing from you. We will get back to you as soon as possible.

Request complete valves catalogue

If you would like to request our complete catalogue "Valves and Controls" as a PDF or as a printed version, please fill out the form below.