The force (1), generated by the actuation, acts through the lever (2), the tappet (3) on the ball(s) (4) and presses it out of the right valve seat (5) and into the left valve seat (5). This is used to connect lines P and A and shut o line T, see Example. The ring (6) supports the fl ange seal from the inside. The volume fl ow is limited by the entire fl ow resistance.
The 3/2-way valve is provided with a „negative overlap“. During the changeover process, connections P, A and T are briefl y connected with each other. The changeover occurs so fast that the hydraulic effects are negligible. By design, a 3/2-way valve always requires the connection of a T-connector; only then a proper switching function can be ensured.
Depending on the design of the valve insert a valve with the basic position „AT NO“ (lines A and T are connected) or „PA NO“ (lines P and A are connected) is provided.
General | |
Weight | 3,9kg |
Installation position | any |
Ambient temperature | -10 to 50°C (Hydraulikmedien Vorgaben beachten) |
Material Valve parts Material Seals | Stainless steel, bronze except electromagnet NBR, PTFE |
Hydraulic | |
max. operating pressure of connector P | 480bar |
max. operating pressure of connector A | 480bar |
max. operating pressure of connector T | 50bar |
max./min. control pressure of connector Z | siehe Bestellangaben |
max. volume flow P->A | 10 l/min |
max. volume flow A->T | 10 l/min |
specified direction of flow | P->A, A->T |
Pressure fluid - Medium - Temperature range - Medium - Quality - Cleanliness class, filter fineness - Viscosity | water, HFA 5 bis 50°C see Hauhinco requirements on water and HFA media class 20/18/15, filter fineness 25µm 0,6 bis 100 mm²/s |
Pressure fluid - Medium - Temperature range - Medium - Quality - Cleanliness class, filter fineness - Viscosity | mineral oil, HLP -10 bis 50°C acc. to DIN 51524 Class 20/18/15, filter fineness 25µm 0,6 bis 100 mm²/s |
Use of other pressure fluids on request. | |
The covers (6) are designed with a viscosity of approx. 1.0 mm²/s; if a medium with a substantially different viscosity is used, the covers must be selected such that the maximum admissible volume flow is not exceeded. | |
Elektric | |
Voltage | 12 VDC, max. 15 VDC |
Current | 0,2 A |
Power consumption | 2,24 W |
Operating time | 100% ED |
Degree of protection acc. to EN60529 | Body IP54, electrical connection IP65 |
Protection against ignition according to EN 50020 | I 2G EEX ia II T6; I M2 EEx ia |
max. switching rate | 1 Hz |
Included in the scope of supply | |
Mounting screws of the valve | Cheese-head screw M6 |
Cable socket of the valve solenoid | Hirschmann cable socket G - series |
Description | Nominal size | Weight | Max. pressure | Basic position | Voltage | Note | Article number |
---|---|---|---|---|---|---|---|
3/2-way valve DN3 PN480 | DN3 | 3,9kg | 480bar | A->T NO | 12VDC | solenoid actuation | 6269591 |
3/2-way valve DN3 PN480 | DN3 | 3,9kg | 480bar | P->A NO | 12VDC | solenoid actuation | 6269605 |